Dimensional Standards - Residential Districts
|
|
RA20
|
R15S
|
R9S
|
R6S
|
RMF
|
RMH
|
RHD
|
1.
Min. Lot Size
(sq. ft.)
(Single-family) |
20,000
|
15,000
|
9,000
|
6,000
|
6,000
|
5,000
|
6,000
|
2.
Min. Lot Size
(sq. ft.)
(Two-family attached) |
|
|
|
|
9,000
|
|
9,000
|
3.
Min. Lot Size
(sq. ft.)
(Multifamily) |
|
|
|
|
|
|
|
4.
Min Lot Size
(sq. ft.) if Water and Sewer are Available |
10,000
|
10,000
|
9,000
|
6,000
|
6,000
|
5,000
|
6,000
|
| 5.
Min. Lot Width (ft.) (Single-family) |
100
|
80
|
70
|
60
|
60
|
50
|
60
|
| 6.
Min Lot Width (ft.) (Two-family attached) |
|
|
|
|
80
|
|
80
|
| 7.
Min. Lot Width (ft.) Multifamily |
|
|
|
|
|
|
|
| 8.
Min. Front Yard Setback (ft.) |
40
|
30
|
25
|
25
|
30
|
40*
|
20
|
| 9.
Min. Side Yard Setback (ft.) |
15
|
10
|
10
|
8
|
8
|
8
|
8**
|
| 10.
Min. Corner Lot Side Yard Setback (ft.) |
25
|
20
|
20
|
20
|
20
|
20
|
20
|
| 11.
Min. Rear Yard Setback (ft.) |
30
|
30
|
20
|
15
|
15
|
8**
|
15**
|
| 12.
Maximum Height (ft.) |
50
|
50
|
50
|
50
|
50
|
50
|
50
|
| 13.
Max. Building Coverage (percentage of lot) |
40
|
40
|
40
|
40
|
50
|
40
|
50
|
* A twenty (20) foot setback is required if a lot fronts on a private
street.
** Where stricter, bufferyard requirements
shall prevail.
Dimensional Standards - Institutional and Commercial Districts
|
|
O&I
|
B1H
|
B2
|
B3
|
B4
|
| 1.
Min. Lot Size (sq. ft.) |
7,500
|
|
20,000
|
10,000
|
6,000
|
2.
Min. Lot Size (sq. ft.)
(Two-family attached) |
|
|
|
|
|
3.
Min. Lot Size (sq. ft.)
(Multifamily) |
|
|
|
|
|
4.
Min. Lot Size (sq. ft.)
if Water and Sewer are Available |
7,500
|
|
20,000
|
10,000
|
6,000
|
5.
Min. Lot Width (ft.)
(Single-family or two-family attached) |
60
|
30*
|
100
|
100
|
60
|
6.
Min. Lot Width (ft.)
(Multifamily) |
|
|
|
|
|
| 7.
Min. Front Yard Setback (ft.) |
30
|
|
50
|
50
|
25
|
| 8.
Min. Side Yard Setback (ft.) |
8**
|
***
|
20
|
10
|
***
|
| 9.
Min. Corner Lot Side Yard Setback (ft.) |
15
|
|
25
|
25
|
25
|
| 10.
Min. Rear Yard Setback (ft.) |
15
|
***
|
20
|
20
|
10
|
| 11.
Maximum Height (ft.) |
96
|
96
|
****
|
****
|
50**
|
| 12.
Max. Building Coverage (percentage of lot) |
40
|
|
|
|
40
|
* This requirement applies only for lots which have never been built
upon, as of the effective date of this Ordinance. Lots upon which
buildings have been built will not have to meet this requirement.
** Where stricter, bufferyard requirements
shall prevail.
*** No setback required unless abutting residential district, then ten
(10) foot setback required.
**** Buildings over fifty (50) feet in height must be set back from the
front lot line one (1) foot for every two (2) feet in excess of fifty
(50) feet in height.
Dimensional Standards - Industrial Districts
| |
I1
|
I2
|
AP
|
| 1.
Min. Lot Size (sq. ft.) |
20,000
|
20,000
|
217,800
|
2.
Min. Lot Size (sq. ft.)
if Water and Sewer are Available |
20,000
|
20,000
|
217,800
|
3.
Additional Lot Area
per Additional Unit (sq. ft.) |
|
|
|
| 4.
Min. Lot Width (ft.) |
100
|
100
|
100
|
5.
Min. Lot Width
per Additional Unit (ft.) |
|
|
|
| 6.
Min. Front Yard Setback (ft.) |
25*
|
25*
|
150
|
| 7.
Min. Side Yard Setback (ft.) |
*
|
*
|
100**
|
| 8.
Min. Corner Lot Side Yard Setback (ft.) |
25*
|
25*
|
100
|
| 9.
Min. Rear Yard Setback (ft.) |
*
|
*
|
25
|
| 10.
Maximum Height (ft.) |
***
|
***
|
|
|
11. Max. Building
Coverage
(percentage of lot)
|
60
|
60
|
|
* A fifty (50) foot setback is required for a lot abutting a residential
district or a public street or waterway separating the lot from a residential
district.
** Where stricter, bufferyard requirements
shall prevail.
*** Buildings over fifty (50) feet in height must be set back from the
front lot line one (1) foot for every two (2) feet in excess of fifty
(50) feet in height.
|